Manage stand orders
Select Option

AXS Motionsystem Ltd.

Erzsebet U. 9., 1045 Budapest
Hungary

Submit your contact details

Provide your contact details to the exhibitor. Optionally, you may also add a personal message.

Please log in

You must be logged in to send the contact request.

An error has occurred

Please check your internet connection or try again later.

Message has been sent

Your message to the exhibitor was sent successfully.

Hall map

A+A 2021 hall map (Hall 10): stand F35

Fairground map

A+A 2021 fairground map: Hall 10

Contact

Lajos Szekely

Managing director

Phone
+36 (20) 934 7824

Email
szekely.lajos@axsmotionsystem.hu

Viktor Nagy

Sales Manager

Phone
+36 (70) 292 4421

Email
nagy.viktor@axsmotionsystem.hu

Please log in

You must be logged in to use matchmaking

Please log in for matchmaking

Registration is required to use the networking service and a separate registration for matchmaking. Please register for Matchmaking first.

Let's get started!

Welcome to Matchmaking. Would you like to get in touch with ?

Visit us

Hall 10 / F35

26 Oct 2021

Topic

11:00 - 11:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

13:00 - 13:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

15:00 - 15:45

AXS System show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

27 Oct 2021

Topic

11:00 - 11:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

13:00 - 13:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

15:00 - 15:45

AXS System show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

28 Oct 2021

Topic

11:00 - 11:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

13:00 - 13:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

15:00 - 15:45

AXS System show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

29 Oct 2021

Topic

11:00 - 11:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

13:00 - 13:45

AXS System Show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

15:00 - 15:45

AXS System show

The AXS Ergonomics Evaluation System can be tested in practice

More Less

Our range of products

Product categories

  • 03  Components, Sourcing & Services
  • 03.03  Services and consultancies
  • 03.03.04  Safety audit and certification

Safety audit and certification

  • 04  Health at work
  • 04.01  Works doctor and practice
  • 04.01.04  Ergonomic equipment

Ergonomic equipment

Our products

Product category: Ergonomic equipment

AXS Motionsysteme Ltd

AXS Ergonomic Evaluating System is an integrated unit of two items. Using AXS Motion Digitizer System all kind of movements as well as the power impulses on hands can be precisely digitally recorded. Ergonomic evaluation can be practically completely automatically – just on site of recording – performed on the basis of data using AXS Ergonomic Evaluating Software.

MOTION DIGITIZER SYSTEM
The motion digitizer unit is a sensor net which consists of 18 units suitable for collecting data necessary to ergonomic analyses and with which movement of body can be digitally recorded continuously.
The system’s speciality is that there is no need for magnetic orientation to determine spatial positions of every single sensor and this way it can function reliably in any industrial environment. The patented process of AXS determines actual position of body from angles made by sensors in relation with each other. Data of sensors are collected by the central unit that makes a datafile suitable for processing and which can be loaded in processing software either through Wi-Fi access or from SD card.
Insoles and gloves - can be connected to sensor net - contain pressure sensors that record power impulses happen on the given surface.
The sensor net is fixed on the cooperating person using a specially developed sensor-cloth. This cloth was tested regarding work safety and it can be safely worn also in operating workplaces.

ERGONOMIC EVALUATING SOFTWARE
Datafile prepared by central unit is processed in AXS Ergonomic Evaluating Software. Using the software, the ergonomist can perform the entire ergonomic analysis of a given workplace. Decisions to be made during analysis are supported by a control video recording recorded simultaneously with digital recording that can be fully synchronized with the digital recording.
The ergonomist can make established decisions on the basis of measured precise motion data and pressure data, while without AXS Ergonomic Evaluating System the ergonomist can only rely on her/his observations and estimations.
Outcome of analysis can be displayed on results board belonging to given ergonomic evaluating methodology and can be exported to an Excel or pdf file. Furthermore, the entire process of analysis can also be exported to video file so this way the ergonomist can precisely show the engineers dealing with development of workplace where possible problems arise.
On the basis of results of more thousands performed measurements it can safely be stated that AXS Ergonomic Evaluating System gives a much more precise result than that can be obtained on the basis of observations and analyses can be performed much quicker than in the conventional way.

WHY AXS ERGONOMIC EVALUATING SYSTEM
Results of ergonomic risk assessments are based on estimations in 90 percent and on measured data only in 10 percent. The posture and the continuous alteration of it that is the basis of analysis as well as power impulses that occur meanwhile cannot be measured precisely with observation method. The basis data of analysis depend on the experience and perceptibility of  the ergonomist performing observation.
AXS Motion Digitizer System is capable of performing precise measurement on body movement, power impulses and bow/turn of spine in a unique way with the assistance of the used 18 sensors. On the basis of measured data, according to the requested ergonomic methodology, evaluation can immediately be performed with AXS Ergonomic Evaluating Software after recording. Assessment and evaluation of a workplace can be performed in on the average of 20-30 minutes. The digital recording can be replayed in 3D over and over again in any visual angle and this way dangerous movements can be seen immediately and the ergonomist can supply adequate and confirmative data to the designers in order to improve the workplace.

More Less

About us

Company portrait

Being pioneer solution-supplier of digital ergonomic analyses, AXS Motionsystem Kft. has opened new dimensions in the world of expert systems based on wearable technology.
Our mission is to support the establishment of healthy and safe workplaces!
Workplaces designed on the basis of reliable ergonomic analyses do not harm health of employees, enhance work safety and enable more effective production. Healthy and safe workplace is of importance for everyone. It is good for You and good for business.
AXS Ergonomic Evaluating System is an integrated unit of two items. Using AXS Motion Digitizer System all kind of movements as well as the power impulses on hands can be precisely digitally recorded. Ergonomic evaluation can be practically completely automatically – just on site of recording – performed on the basis of data using AXS Ergonomic Evaluating Software.

 

Company data

Export content > 75%
Number of employees 1-19
Foundation 2014
Area of business
  • Technical supervision, technical inspections
  • Company doctor, occupational, travel and environmental health
  • Science and research
Target groups
  • Work safety specialists (safety engineers and technicians)
  • Company doctors, occupational health practitioners and psychologists
  • Planning and construction

Company information as a PDF file